Overview
Group
Quick Info

Windows NT
Yes
Win95
No
Win32s
No
Import Library
netapi32.lib
Header File
lmwksta.h
Unicode
WinNT
Platform Notes
All LanMan APIs are UNICODE only

NetWkstaSetInfo

The NetWkstaSetInfo function configures a workstation. This information remains in effect after the system has been reinitialized.

Security Requirements

Only members of the Administrators local group can successfully execute NetWkstaSetInfo on a remote server.

NET_API_STATUS NetWkstaSetInfo(

LPTSTR servername,

DWORD level,

LPBYTE buffer,

LPDWORD parm_err

);

Parameters

servername

Pointer to a Unicode string containing the name of the remote server on which the function is to execute. A NULL pointer or string specifies the local computer.

level

Specifies one of the following values to set the level of information provided.

Value
Meaning
100
The buffer parameter points to a WKSTA_INFO_100 structure.
101
The buffer parameter points to a WKSTA_INFO_101 structure.
102
The buffer parameter points to a WKSTA_INFO_102 structure.
302
The buffer parameter points to a WKSTA_INFO_302 structure.
402
The buffer parameter points to a WKSTA_INFO_402 structure.
1101
The buffer parameter points to a WKSTA_USER_INFO_1101 structure.

In addition, the structures WKSTA_USER_INFO_502, WKSTA_USER_INFO_1010-1013, WKSTA_USER_INFO_1018, WKSTA_USER_INFO_1023, WKSTA_USER_INFO_1027, WKSTA_USER_INFO_1028, WKSTA_USER_INFO_1032, WKSTA_USER_INFO_1033, WKSTA_USER_INFO_1035, and WKSTA_USER_INFO_1041-1062 should not be set by the user.

buffer

Pointer to the buffer in which the data set with the level parameter is stored.

parm_num

Determines whether the buffer parameter contains a complete WKSTA_INFO_X (where Xis the level) structure or a single structure component. If parm_num is set to PARMNUM_ALL, buffer must point to a WKSTA_INFO_X structure. Otherwise, only one element is changed, and parm_num must point to the single element to change.

Not all elements can be changed. Only those elements that have a specific PARMNUM constant value defined can be set. The following possible values are defined.

Value
Component to Set
PARMNUM_ALL
All elements
WKSTA_CHARWAIT_PARMNUM
wki0_charwait
WKSTA_CHARTIME_PARMNUM
wki0_chartime
WKSTA_CHARCOUNT_PARMNUM
wki0_charcount
WKSTA_ERRLOGSZ_PARMNUM
wki0_errlogsz
WKSTA_PRINTBUFTIME_PARMNUM
wki0_printbuftime
WKSTA_WRKHEURISTICS_PARMNUM
wki0_wrkheuristics
WKSTA_OTHDOMAINS_PARMNUM
wki1_oth_domains

parm_err

Optional pointer to a DWORD that contains the index of the first parameter that causes ERROR_INVALID_PARAMETER. If NULL, the parameter is not returned on error.

Remarks

You must be a member of the Administrators local group to successfully execute NetWkstaSetInfo on a remote server or on a computer that has local security enabled. NetWkstaSetInfo does not change values in the LANMAN.INI file. Values set by previous calls to NetWkstaSetInfo can be overwritten when workstation parameters are reset. When the Workstation service is stopped and restarted, parameters are reset to the default values specified in the LANMAN.INI file unless overwritten by command-line parameters.

Domain names in the wki1_oth_domains member of the WKSTA_USER_INFO_1101 structure are separated by spaces. An empty list is valid. A null pointer means to leave the member unmodified. The wki1_oth_domains member cannot be set with MS-DOS. When setting this element, NetWkstaSetInfo rejects the request if the name list was invalid or if a name could not be added to one or more of the network adapters managed by LAN Manager.

See Also

NetWkstaGetInfo

Software for developers
Delphi Components
.Net Components
Software for Android Developers
More information resources
MegaDetailed.Net
Unix Manual Pages
Delphi Examples
Databases for Amazon shops developers
Amazon Categories Database
Browse Nodes Database